Обработка
Transforming dangerous medical waste into safe municipal waste
Inside the FHT Treatment Cycle
Our friction-based treatment process transforms dangerous medical waste into safe, sterile municipal waste in a matter of minutes. Discover how the cycle works step-by-step.
Waste Loading & Pre-shredding
Medical waste is loaded into the treatment chamber either manually or automatically. The heavy-duty rotor immediately begins pre-shredding the materials to optimize surface area.
High-Speed Friction & Heating
As the shredding accelerates, the intense mechanical friction generates rapid heating. The temperature inside the chamber steadily climbs toward the sterilization threshold.
Sterilization Phase (150°C)
The temperature hits 150°C (302°F). Water contained within the waste vaporizes, creating a moist heat environment. This temperature is maintained to guarantee a 6 Log10 reduction of all pathogens.
Cooling & Safe Discharge
Water is injected to rapidly cool the sterile material down to a safe handling temperature. The final output—a dry, unrecognizable confetti—is automatically discharged.
Key Treatment Metrics
Our FHT treatment process strictly complies with international environmental and health regulations, ensuring total safety for both operators and the community.